Print…

Procurou por: certipur+merck


83  resultados encontrados

Sort Results

Visualização em Lista Easy View (new)
SearchResultCount:"83"
Descrição: Avantor® ACE® HILIC-B columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Código de Artigo: HILB-5-1030
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® HILIC-A columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Código de Artigo: HILA-3-2546U
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® HILIC-N columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Código de Artigo: ACETHILN-3-0103GD
UOM: 1 * 5 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® HILIC method development kits offer all three Avantor® ACE® proprietary HILIC phases (HILIC-A, HILIC-B and HILIC-N) in one kit. These phases offer alternative HILIC selectivity to each other, and have been developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Código de Artigo: MDKH-3-2503U
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® HILIC-B columns have been designed specifically for HILIC applications and are especially useful for the separation of polar analytes. These columns are part of a suit of 3 proprietary HILIC columns (HILIC-A, HILIC-B and HILIC-N) developed to enable chromatographers to achieve reproducible and successful HILIC separations using a systematic approach to method development.
Código de Artigo: HILB-5-2502U
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® Glycan is a high performance stationary phase designed for the analysis of 2-aminobenzamide labelled glycans by hydrophilic interaction liquid chromatography (HILIC). These ultra-inert, high efficiency columns provide excellent column lifetime and reproducibility with buffers and mobile phases typically utilised for glycan analysis. Two particle sizes are available to enable both high resolution and rapid separations on HPLC and UHPLC instrumentation.
Código de Artigo: EXL-1116-1546
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® ACE® Method Development Kits (MDK) are designed to maximize selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness. A complete range of kits for all requirements is available, including porous, solid core, HILIC and bioanalytical 300 Å column kits. These kits group together the essential column chemistries for method development and are available in a wide range of column formats.
Código de Artigo: MDKU-25-1546U
UOM: 1 * 1 KIT
Fornecedor: Avantor


Descrição: Avantor® ACE® Method Development Kits (MDK) are designed to maximize selectivity, offering a powerful and reliable approach to UHPLC/HPLC method development. Based upon an ultra-inert, high efficiency silica, Avantor® ACE® phases incorporate the latest developments in LC stationary phase design, providing chromatographers with more choices for alternative selectivity, without compromising stability or robustness. A complete range of kits for all requirements is available, including porous, solid core, HILIC and bioanalytical 300 Å column kits. These kits group together the essential column chemistries for method development and are available in a wide range of column formats.
Código de Artigo: MDKU-5-2503U
UOM: 1 * 1 KIT
Fornecedor: Avantor


Descrição: Avantor® Alltima HP columns features hydrophilic interaction chromatography that uses small amounts of water for increased sensitivity with microbore applications.
Código de Artigo: HICH86466
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: Avantor® Alltima HP columns features hydrophilic interaction chromatography that uses small amounts of water for increased sensitivity
with microbore applications.
Código de Artigo: HICH86463
UOM: 1 * 1 unid.
Fornecedor: Avantor


Descrição: The selectivity offered by ZIC®-HILIC is suitable for a wide variety of molecules containing hydrophilic or ionisable functional groups. This includes compounds such as carbohydrates, metabolites, acids and bases, organic and inorganic ions, metal complexes, amino acids, peptides, protein digests, plant and cell extracts, plus much more. Such compounds are normally characterised by a small or negative LogP value and have poor retention on reversed-phase columns.
Código de Artigo: 1.50490.0001
UOM: 1 * 5 unid.
Fornecedor: Merck

MSDS


Descrição: Ascentis® Express HILIC high-speed, high-performance liquid chromatography columns are based on Fused-Core® particle design. The Fused-core particle provides a thin porous shell of high-purity silica surrounding a solid silica core.
Código de Artigo: 50256-U
UOM: 1 * 1 unid.
Fornecedor: Merck


Descrição: ZIC®-pHILIC has the same stationary phase as ZIC®-HILIC, but is instead based on a polymeric particle for enhanced pH stability. The lack of silica practically nullifies background in high sensitivity detectors such as charged aerosol used for determination of organic and inorganic ions.
Código de Artigo: 1.50459.0001
UOM: 1 * 1 unid.
Fornecedor: Merck

MSDS


Descrição: ZIC®-cHILIC is based on the same technology platform as ZIC®-HILIC, but has a different functional group and an improved manufacturing procedure. The different charge orientation of the zwitterionic functional group leads to a different – and complementary – selectivity for polar hydrophilic compounds. This selectivity is especially beneficial for hydrophilic compounds that are negatively charged, positively charged, zwitterionic or neutral, for example, organic acids, amino acids, metabolites, aminoglycosides and nucleotides.
Código de Artigo: 1.50670.0001
UOM: 1 * 1 unid.
Fornecedor: Merck

MSDS


Descrição: BIOshell™ Glycan HPLC columns are specifically engineered to deliver fast, high resolution, reproducible gylcan identification using HILIC chromatography.
Código de Artigo: 50994-U
UOM: 1 * 1 unid.
Fornecedor: Merck


Descrição: These columns offer a unique HILIC selectivity and low ion exchange activity. Based on Core Enhanced Technology, they provide fast, high resolution separations without the elevated back pressures required by sub-2 µm particles.
Código de Artigo: 554-2329
UOM: 1 * 1 unid.
Fornecedor: Thermo Fisher Scientific


81 - 83 of 83