Print…

Procurou por: Viscosímetros capilares

Calibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary. Since the driving force is gravity and cannot be varied, the standardized glass tubes produce more reliable results. Common Ostwald and Ubbelohde capillary viscometers are inexpensive alternatives to digital versions when determining material properties.

Calibrated with clear markings, the capillary viscometers support visual viscosity measurements of liquids. The direct or reverse flow styles have respectively positioned reservoirs to calculate the time it takes a specific fluid quantity to flow through the capillary. Since the driving force is gravity and cannot be varied, the standardized glass tubes produce more reliable results. Common Ostwald and Ubbelohde capillary viscometers are inexpensive alternatives to digital versions when determining material properties.


176  resultados encontrados

Sort Results

Visualização em Lista Easy View (new)
SearchResultCount:"176"
Descrição: Viscosímetro capilar, for manual measurements, Cannon-Fenske, Calibrado, Gama: 0,8 - 3,2 mm²/s, Constante: 0,004 K, Comprimento: 245 mm, Ø int.: 0,44 mm
Código de Artigo: SCOI285403515
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, for manual measurements, Cannon-Fenske, Calibrado, Gama: 1600 - 8000 mm²/s, Constante: 8 K, Comprimento: 245 mm, Ø int.: 3,20 mm
Código de Artigo: SCOI285403601
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, for manual measurements, Cannon-Fenske, Calibrado, Gama: 1,6 - 6,4 mm²/s, Constante: 0,008 K, Comprimento: 245 mm, Ø int.: 0,54 mm
Código de Artigo: SCOI285403523
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, Ostwald, Não calibrado, Gama: >0,3 mm²/s, Constante: 0,004 K, Comprimento: 220 mm, Ø int.: 0,30 mm, Volume: 3 ml
Código de Artigo: SCOI285404006
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, Ostwald, Não calibrado, Gama: >10 mm²/s, Constante: 0,1 K, Comprimento: 220 mm, Ø int.: 0,70 mm, Volume: 3 ml
Código de Artigo: SCOI285404047
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, Ostwald, Não calibrado, Gama: >5,5 mm²/s, Constante: 0,07 K, Comprimento: 220 mm, Ø int.: 0,60 mm, Volume: 3 ml
Código de Artigo: SCOI285404039
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, Ostwald, Não calibrado, Gama: >2,5 mm²/s, Constante: 0,03 K, Comprimento: 220 mm, Ø int.: 0,50 mm, Volume: 3 ml
Código de Artigo: SCOI285404022
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, for manual measurements, Cannon-Fenske, Calibrado, Gama: 4000 - 20 000 mm²/s, Constante: 20 K, Comprimento: 245 mm, Ø int.: 4,20 mm
Código de Artigo: SCOI285403618
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, for manual measurements, Cannon-Fenske, Calibrado, Gama: 20 - 100 mm²/s, Constante: 0,1 K, Comprimento: 245 mm, Ø int.: 1,01 mm
Código de Artigo: SCOI285403556
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, Ostwald, Não calibrado, Gama: >1 mm²/s, Constante: 0,01 K, Comprimento: 220 mm, Ø int.: 0,40 mm, Volume: 3 ml
Código de Artigo: SCOI285404014
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Viscosímetro capilar, for manual measurements, Micro-Ubbelohde, Calibrado, Gama: 0,4 - 6 mm²/s, Constante: 0,01 K, Comprimento: 290 mm, Ø int.: 0,40 mm, Volume: 3 − 4 ml
Código de Artigo: 645-0070
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Reverse flow capillary viscometer, for manual measurements, Cannon-Fenske, Para medição manual, Gama: 7 - 35 mm²/s, Constante: 0,035 K, Comprimento: 295 mm, Ø int.: 0,78 mm
Código de Artigo: SCOI285403042
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Reverse flow capillary viscometer, for manual measurements, Cannon-Fenske, Para medição manual, Gama: 1,6 - 6,4 mm²/s, Constante: 0,008 K, Comprimento: 295 mm, Ø int.: 0,54 mm
Código de Artigo: SCOI285403026
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Reverse flow capillary viscometer, for manual measurements, Cannon-Fenske, Para medição manual, Gama: 0,4 - 1,6 mm²/s, Constante: 0,002 K, Comprimento: 295 mm, Ø int.: 0,30 mm
Código de Artigo: SCOI285403001
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Reverse flow capillary viscometer, for manual measurements, Cannon-Fenske, Para medição manual, Gama: 0,8 - 3,2 mm²/s, Constante: 0,004 K, Comprimento: 295 mm, Ø int.: 0,42 mm
Código de Artigo: SCOI285403018
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


Descrição: Reverse flow capillary viscometer, for manual measurements, Cannon-Fenske, Para medição manual, Gama: 3 - 15 mm²/s, Constante: 0,015 K, Comprimento: 295 mm, Ø int.: 0,63 mm
Código de Artigo: SCOI285403034
UOM: 1 * 1 unid.
Fornecedor: SI Analytics


49 - 64 of 176